21 research outputs found

    Insights into the Skeletonization, Lifestyle, and Affinity of the Unusual Ediacaran Fossil Corumbella

    Get PDF
    The Ediacaran fossil Corumbella is important because it is hypothesized to be a scyphozoan\ud cnidarian, and thus might be one of the rare examples of bona fide Neoproterozoic nimals.\ud Unfortunately, its mode of life, style of skeletonization, and taxonomic affinity have been very controversial. Here, we use X-ray micro-CT, SEM, and taphonomic analysis to compare preservational modes of Corumbella, in order to better understand the symmetry, mode of construction, preservational style, and taxonomy of this group. Results suggest that articulated and disarticulated specimens of Corumbella from the Ediacaran of Brazil, Paraguay, and the United States, although sometimes preserved very differently, represent\ud the same taxon—Corumbella werneri. Corumbellids had a thick but flexible theca and probably lived with their basalmost part anchored in the sediment, much like Conotubus. When considered together, these results suggest that Corumbella was one of the first animals to build a skeleton, employing a lamellar microfabric similar to conulariids.FAPESP (Proc. 2009/02312-4)NAPAstrobio (PRP-USP)FAPESP (Proc. 2011/50242-5)CNPq (562143/ 2010-6, 458555/2013-4)CAPES.Astrobiology Laboratory (AstroLab, IAG-USP)LNNano/CNPEMNP-BioMa

    Near-field ptychography: Phase retrieval for inline holography using a structured illumination

    Get PDF
    Inline holography is a common phase-contrast imaging method which uses free-space propagation to encode the phase signal into measured intensities. However, quantitative retrieval of the sample's image remains challenging, imposing constraints on the nature of the sample or on the propagation distance. Here, we present a way of simultaneously retrieving the sample's complex-valued transmission function and the incident illumination function from near-field diffraction patterns. The procedure relies on the measurement diversity created by lateral translations of the sample with respect to a structured illumination. The reconstruction approach, in essence identical to that employed in ptychography, is applied to hard X-ray synchrotron measurements and to simulations. Compared to other inline holography techniques, we expect near-field ptychography to reduce reconstruction artefacts by factoring out wavefront imperfections and relaxing constraints on the sample's scattering properties, thus ultimately improving the robustness of propagation-based X-ray phase tomography

    Absorption and Phase Contrast X-Ray Imaging in Paleontology Using Laboratory and Synchrotron Sources

    No full text
    X-ray micro-computed tomography (μCT) is commonly used for imaging of samples in biomedical or materials science research. Owing to the ability to visualize a sample in a nondestructive way, X-ray μCT is perfectly suited to inspect fossilized specimens, which are mostly unique or rare. In certain regions of the world where important sedimentation events occurred in the Precambrian geological time, several fossilized animals are studied to understand questions related to their origin, environment, and life evolution. This article demonstrates the advantages of applying absorption and phase-contrast CT on the enigmatic fossil Corumbella werneri, one of the oldest known animals capable of building hard parts, originally discovered in Corumbá (Brazil). Different tomographic setups were tested to visualize the fossilized inner structures: a commercial laboratory-based μCT device, two synchrotron-based imaging setups using conventional absorption and propagation-based phase contrast, and a commercial X-ray microscope with a lens-coupled detector system, dedicated for radiography and tomography. Based on our results we discuss the strengths and weaknesses of the different imaging setups for paleontological studies

    X-ray near-field ptychography for optically thick specimens

    No full text
    Inline holography, like other lensless imaging methods, circumvents limitations of x-ray optics through an a posteriori phase-retrieval step. However, phase retrieval for optically thick, i.e., strongly absorbing and phase shifting, specimens remains challenging. In this paper, we demonstrate that near-field ptychography can be used to efficiently perform phase retrieval on a uranium sphere with a diameter of about 46 \u3bcm, which acts as an optically thick sample. This particular sample was not accessible by inline holography previously. The reconstruction is based on a statistical model and incorporates partial coherence by decomposing the illumination into coherent modes. Furthermore, we observe that phase vortices, which can occur as artifacts during the reconstruction, pose a greater challenge than in far-field methods. We expect that the methods described in this paper will allow production of reliable phase maps of samples which cannot be accessed by inline holography

    X-ray phase-contrast tomosynthesis for improved breast tissue discrimination.

    No full text
    Attenuation-based tomosynthesis has proven to successfully resolve the glandular tissue overlap present in mammography. However, the ability of tomosynthesis to differentiate tumorous and glandular tissue remains limited, due to the small differences in X-ray attenuation in breast tissue. One possibility to overcome this limitation and to further increase the diagnostic value of tomosynthesis exams, is the application of recently developed grating-based phase-contrast methods, which provide complementary information on the phase shift and the local scattering power of the sample. In this study, we report on first phase-contrast breast tomosynthesis results of a mastectomy sample slice with an invasive ductal carcinoma

    X-ray nanotomography using near-field ptychography

    No full text
    International audiencePropagation-based imaging or inline holography in combination with computed tomography (holotomography) is a versatile tool to access a sample's three-dimensional (3D) micro or nano structure. However, the phase retrieval step needed prior to tomographic reconstruction can be challenging especially for strongly absorbing and refracting samples. Near-field ptychography is a recently developed phase imaging method that has been proven to overcome this hurdle in projection data. In this work we extend near-field ptychography to three dimensions and we show that, in combination with tomography, it can access the nano structure of a solid oxide fuel cell (SOFC). The quality of the resulting tomographic data and the structural properties of the anode extracted from this volume were compared to previous results obtained with holotomography. This work highlights the potential of 3D near-field ptychography for reliable and detailed investigations of samples at the nanometer scale, with important applications in materials and life sciences among others. (C) 2015 Optical Society of Americ

    Translation of atherosclerotic plaque phase-contrast CT imaging from synchrotron radiation to a conventional lab-based X-ray source.

    Get PDF
    OBJECTIVES: Phase-contrast imaging is a novel X-ray based technique that provides enhanced soft tissue contrast. The aim of this study was to evaluate the feasibility of visualizing human carotid arteries by grating-based phase-contrast tomography (PC-CT) at two different experimental set-ups: (i) applying synchrotron radiation and (ii) using a conventional X-ray tube. MATERIALS AND METHODS: Five ex-vivo carotid artery specimens were examined with PC-CT either at the European Synchrotron Radiation Facility using a monochromatic X-ray beam (2 specimens; 23 keV; pixel size 5.4 µm), or at a laboratory set-up on a conventional X-ray tube (3 specimens; 35-40 kVp; 70 mA; pixel size 100 µm). Tomographic images were reconstructed and compared to histopathology. Two independent readers determined vessel dimensions and one reader determined signal-to-noise ratios (SNR) between PC-CT and absorption images. RESULTS: In total, 51 sections were included in the analysis. Images from both set-ups provided sufficient contrast to differentiate individual vessel layers. All PCI-based measurements strongly predicted but significantly overestimated lumen, intima and vessel wall area for both the synchrotron and the laboratory-based measurements as compared with histology (all p0.53 per mm(2), 95%-CI: 0.35 to 0.70). Although synchrotron-based images were characterized by higher SNRs than laboratory-based images; both PC-CT set-ups had superior SNRs compared to corresponding conventional absorption-based images (p0.98 and >0.84 for synchrotron and for laboratory-based measurements; respectively). CONCLUSION: Experimental PC-CT of carotid specimens is feasible with both synchrotron and conventional X-ray sources, producing high-resolution images suitable for vessel characterization and atherosclerosis research

    Corumbella werneri: ultrastructure of theca.

    No full text
    <p>(A) GP1E-574a: three-dimensional specimen with theca. (B) 3D-rendered microCT of <i>Corumbella</i> theca,flipped by 180° compared to (A): interior view and detail for lamellae microfabric and plates (black arrow). (C) 3D-rendered microCT of <i>Corumbella</i> theca (A) without flipping in C1 and C2, with details of rings (white arrow). (D) compression and fragmentation along theca. D1 shows a transversal section in the fossil structure. Flipped by 180° of it produces D2, with details of small breakages (white arrow). (E) Details of lamellar plates by SEM (black arrow) and (F) pores in plates (black dashed arrow). Scale: 1mm.</p

    Simplified map of South America (A) with detail of the geological map of the Paraguay Belt (B), and Corumbá Group (C) Modified from Oliveira, 2010, [48].

    No full text
    <p>Simplified map of South America (A) with detail of the geological map of the Paraguay Belt (B), and Corumbá Group (C) Modified from Oliveira, 2010, [<a href="http://www.plosone.org/article/info:doi/10.1371/journal.pone.0114219#pone.0114219.ref048" target="_blank">48</a>].</p
    corecore